Upgrade Procedure
To upgrade the OneView™ software on your ONS-NC600, please carefully follow the upgrade instructions or contact Optigo Networks at support@optigo.net or 1-800-629-6559 for assistance.
To upgrade the OneView™ software on your ONS-NC600, please carefully follow the upgrade instructions or contact Optigo Networks at support@optigo.net or 1-800-629-6559 for assistance.
WARNING
If your OneView system's 'Factory Default Version' is older than 4.2.0-065, please contact Optigo tech support for assistance before you attempt to upgrade your system.
Filename: ons-nc600-fw-4.4.0-168.optg
SHA256 checksum: 6e5d39550881a0593239ea042c474781c7cb352e662c644aa4a7adf6adf42959
New Features & Improvements
New Features & Improvements
- Router management for supported routers.
- Miscellaneous GUI bugs fixed.
- Fixed bug where the device databases were not being synced on redundant systems.
- Improved report generation performance.
- Fixed bug where duplicate MAC addresses could be entered for IP reservations within the same subnet.
- Fix bug that prevented PoE from being disabled on some ports on ONS-C801pi and ONS-C1601pi edge switches.
Known Issues & Limitations
- When a Hybrid system is restarted, or resumes operation after a power outage, all of the VLANs on ports configured as 'trunk' will be deleted, except for the lowest one (e.g. a trunk port with VLANs 100, 200, and 300 will now only have 100).
Workaround: Upgrade to the latest version of OneView software. - Plugging in or unplugging Ethernet cables from an ONS-CU-SFP can result in duplicate link notifications appearing on the Notifications screen.
Workaround: Ignore these - the Edge Switch itself is sending this. - Changing port VLANs occasionally throws an error (Spectra Only).
Workaround: Re-attempt VLAN change. - Some downstream traffic does not pass on VLAN 1 with ONS-C801pi and ONS-C1601pi (Spectra Only).
Workaround: Use a VLAN other than 1. - Notifications on the Windows version of Chrome do not work when using "http".
Workaround: Always use "https" (e.g. https://192.168.10.254). - If data traffic (non-management) can reach the Network Controller, then an excessive amount of broadcast (DoS) may cause performance issues with the GUI (OneView).
Workaround: Use a unique VLAN for management (OneView). - Inter-switch traffic on the same EPON (laser) does not increment traffic counters on bandwidth page (Spectra Only).
- The ONS-C4801p in Hybrid mode can cause issues with the topology view.
New and Updated Documentation
The following is a list of documents that have been updated or newly created to support this release of OneView software:
- Connect OneView™ User Guide
- Router Management with OneView™
- OneView™ Supported Routers
- Router Upgrade with OneView™
- Setting Up Redundancy on Optigo Connect Spectra™ Systems
- Setting Up Redundancy on Optigo Connect Spectra™ Systems with a OneView compatible Router
Comments
0 comments
Please sign in to leave a comment.