IMPORTANT
If you're upgrading from version 4.4.3-188 (or older), please make sure you've purchased the appropriate license(s) for your system. If in doubt, please contact Optigo tech support first.
If you're upgrading from version 4.4.3-188 (or older), please make sure you've purchased the appropriate license(s) for your system. If in doubt, please contact Optigo tech support first.
Upgrade Procedure
To upgrade the OneView™ software on your ONS-NC600, please carefully follow the upgrade instructions or contact Optigo Networks at support@optigo.net or 1-800-629-6559 for assistance.
To upgrade the OneView™ software on your ONS-NC600, please carefully follow the upgrade instructions or contact Optigo Networks at support@optigo.net or 1-800-629-6559 for assistance.
Filename: ons-nc600-fw-4.6.0-255.optg
SHA256 checksum: c65182edafecf8203cde6101ac9aa19b4cb20c85e74f8ef07e08d987eaeefc98
New Features & Improvements
New Features & Improvements
- Added support for custom router commands.
- Added support for ONS-C4801p as a Hybrid Aggregation Switch.
- Fixed a bug where ONS-S8 ports could not be configured to accept tagged traffic on VLAN 1.
- Miscellaneous minor bug fixes and stability improvements.
Known Issues & Limitations
- IMPORTANT: The available VLAN range has been reduced from 1-4092 to 1-4050. All VLANs from 4051 onward are now reserved for internal use by OneView. Please contact us if your site is currently making use of a VLAN in the reserved range.
- MAC authorization (e.g. OneClick Secure) has limited traffic blocking capabilities on ONS-CR2440XP edge switches running version 8.40.1981 (or older) firmware. Upgrade the switch's firmware to the latest version.
- The ONS-C4801p in Hybrid mode can cause issues with the topology view.
- In rare cases, bulk assignment of large ranges of VLANs on many trunk ports can result in an ‘HTTP Server Error’ message popup and OneView becoming unresponsive for a few minutes.
Workaround: Close the error message dialog, wait for the system to stabilize, and then, if applicable, re-apply any settings changes that failed to complete. - Plugging in or unplugging Ethernet cables from an ONS-CU-SFP can result in duplicate link notifications appearing on the Notifications screen.
Workaround: Ignore these - the Edge Switch itself is sending this. - Changing port VLANs occasionally throws an error (Spectra Only).
Workaround: Re-attempt VLAN change. - If data traffic (non-management) can reach the Network Controller, then an excessive amount of broadcast (DoS) may cause performance issues with the GUI (OneView).
Workaround: Use a unique VLAN for management (OneView). - Inter-switch traffic on the same EPON (laser) does not increment traffic counters on bandwidth page (Spectra Only).