Upgrade Procedure
To upgrade the OneView™ software on your ONS-NC600, please carefully follow the upgrade instructions or contact Optigo Networks at support@optigo.net or 1-800-629-6559 for assistance.
To upgrade the OneView™ software on your ONS-NC600, please carefully follow the upgrade instructions or contact Optigo Networks at support@optigo.net or 1-800-629-6559 for assistance.
WARNING
If your OneView system's 'Factory Default Version' is older than 4.2.0-065, please contact Optigo tech support for assistance before you attempt to upgrade your system.
Filename: ons-nc600-fw-4.4.0-163.optg
SHA256 checksum: 7dad55f666b1113cf341f0312208fc8819b915b3d700239a220f3691ef14d289
New Features & Improvements
New Features & Improvements
- Router management for supported routers.
Known Issues & Limitations
- A bug in the 'Inter-VLAN Routing' table results in the selection dialog moving down the page when the table starts to get large enough to require scrolling.
Workaround: Keep track of it on the page as you add VLANs and avoid scrolling the 'Inter-VLAN Routing' table when possible. - Currently only supports 100 reserved DHCP addresses.
Workaround: None right now, but a patch will be issued soon. Keep checking our Software page. - Named VLANs are not auto-created when adding a new VLAN ID to an ONS-S8 port.
Workaround: Add the new VLAN ID to an edge switch port first or manually create the named VLAN on either the 'VLANs' or 'VLANs & Subnets' page. - Plugging in or unplugging Ethernet cables from an ONS-CU-SFP can result in duplicate link notifications appearing on the Notifications screen.
Workaround: Ignore these - the Edge Switch itself is sending this - Changing port VLANs occasionally throws an error (Spectra Only).
Workaround: Re-attempt VLAN change. - Some downstream traffic does not pass on VLAN 1 with ONS-C801pi and ONS-C1601pi (Spectra Only).
Workaround: Use a VLAN other than 1. - Notifications on the Windows version of Chrome do not work when using "http".
Workaround: Always use "https" (e.g. https://192.168.10.254). - If data traffic (non-management) can reach the Network Controller, then an excessive amount of broadcast (DoS) may cause performance issues with the GUI (OneView).
Workaround: Use a unique VLAN for management (OneView). - Inter-switch traffic on the same EPON (laser) does not increment traffic counters on bandwidth page (Spectra Only).
- The ONS-C4801p in Hybrid mode can cause issues with the topology view.
New and Updated Documentation
The following is a list of documents that have been updated or newly created to support this release of OneView software:
Comments
0 comments
Please sign in to leave a comment.